Keysight technologies 1992 2014 ausgabe 4, august 2014 3440190418 3440190418. Use recall menu as a shortcut to recall the last command executed. If you are a firsttime user of the scpi language, you may want to refer to these sections to become familiar with the language before attempting to program the. For additional information about firmware revisions, see appendix a. An introduction to using the agilent 54622d digital oscilloscope, e3631a dc power supply, 34401a digital multimeter, and 33220a arbitrary waveform generator by walter banzhaf, university of hartford, ward college of technology, usa part four the agilent 34401a digital multimeter 1. Set the gpib bus address see chapter 4 in the users guide. Agilent automationready cd agilent io libraries suite. All product documentation, software, and examples are included on the agilent 34401a product reference cdrom. The keysight formerly agilent 34401a digital multimeter is a tool kit of useful testing functions. Agilent 34410a and 34411a multimeters setting the standard. Here it is i am sweeping voltage from 0 to 5 v using agilent e3647a and i am measuring the current with agilent 34401a dmm. For a little more programming flexibility, use the configure command.
Describes how to set the 34401a programming compatibility mode from the front panel of the 34410a and 34411a dmms. Chapter 1 installation and maintenance this chapter contains information on initial inspection, installation, and. Keysight agilent 34401a 1cm details keysight agilent 34401a 1cm digital multimeter, 6. View online or download agilent technologies 34401a user manual. Additionally, the programming commands to set the 34401a compatibility mode are. Agilent 34410a11a command quick reference mikrosys. All of the 33220a product documenation is provided on the agilent 33220a product reference cd. However, transient overvoltages are also present on circuits that are isolated from mains. Agilent 34410a34411a 61 2 digit highperformance multimeters. I cant get the two to trigger simultaneously by observing the vm complete signal on the back. Unless otherwise indicated, this manual applies to all serial numbers. Agilent technologies agilent 34401a 6 digit multimeter users guide. The agilent 34401a are designed to safely withstand occasional transient overvoltages up.
Programming the 3499abc switch and the 34401a dmm to program these instruments, you need to have a gpib or rs232 interface on your pc. Agilent 34401a multimeter uncompromising performance for. If you have questions relating to the operation of the power supply, call 18004524844 in the united states, or contact your nearest agilent technologies sales office. Math functions, such as null, db, dbm, limit test, minmaxavg and dc voltage ratios are easily selected from the clear, logical front panel. Options datasheet search, datasheets, datasheet search site for electronic components and semiconductors, integrated circuits, diodes and other semiconductors. Getting started 1 introduction to the hp34401a digital multimeter the following is a brief overview of the dmm. Move to the next generation 34401a dmm with 100% assurance. Find the best pricing for keysight technologies 34401a by comparing bulk discounts from 3 distributors. The 34401a provides a combination of resolution, accuracy and speed that rivals dmms costing many times more. Programming and syntax guide for sidebyside scpi command comparison of the agilent u2741a 34405a, and 34410a34411a digital multimeters on. Keysight technologies 34401a multimeter, 400 vdc, 10 ma. Agilent 33220a product reference cd product software, programming examples, and manuals. A vertical bar separates multiple parameter choices for a given command string.
Measurements are displayed on a bright, highvisibility readout. Keysight formerly agilent 34401a for lease, rent or buy. In addition to the standard functions youve come to expect from a high quality dmm, you also get many other capabilities, from minmaxavg to builtin limit testing. Ordering informationagilent 34401a multimeteraccessories included. Agilent 34410a11a command quick reference syntax conventions braces enclose the parameter choices for a given command string. Octopart is the worlds source for 34401a availability, pricing, and technical specs and other electronic parts. The examples included use the agilent isdk instrument software development kit in visual basic 6. From my program what i have written i see that the loop itterates only two times per second, which is too slow. Throughout this manual, the following conventions are used for. The agilent technologies 34401a is a 612digit, highperformance.
Keysight 33210a 10 mhz functionarbitrary waveform generator. How to program the 3499abc switch and the 34401a digital. Easily share your publications and get them in front of issuus. Its combination of benchtop and system features makes this multimeter a versatile solution for your measurement needs now and in the future. Issuu is a digital publishing platform that makes it simple to publish magazines, catalogs, newspapers, books, and more online.
Agilent 4294a precision impedance analyzer programming manual eighth edition firmware revisions this manual applies directly to instruments that have the firmware revision 1. If you have questions relating to the operation of the power supply, call 18004524844 in the united states, or contact your. Agilent 34401a multimeter quick reference frontpanel menu reference use recall menu as a shortcut to recall the last command executed. The keysight technologies 34401a multimeter gives you the performance you need for fast, accurate bench and system testing. How to set the 34401a compatibility mode for 34410a and. Hp, alldatasheet, datasheet, datasheet search site for electronic components and. If your hp 34401a fails within three years of purchase, hp will repair or replace it free of charge.
Digit multimeter connect the test leads to the input terminals. Agilent 34401a multimeter, 34401a datasheet, 34401a circuit, 34401a data sheet. Keysight technologies 34401a multimeter, 400 vdc, 10. Unfollow agilent hp 34401a to stop getting updates on your ebay feed. Agilent 34401a manual download by randallprimeaux3355 issuu. Agilent 34401a multimeter data sheet measure up to volts with 6. If you are using the 34401a native labview plug and play driver that ships with labview, then you should find information in the labview help see the attachments. Test lead kit with probe,alligator, and grabberattachments, operatingmanual, service manual,calibration certificate,test report, and power cord. Keysightagilent 34401a1cm details keysightagilent 34401a1cm digital multimeter, 6. Page 1 page 2 restricted rights legend page 3 safety information page 4 page 5 page 6 page 7 page 8 the front panel at a glance page 9 page 10 page 11 chassis ground page 12 in this book page table of contents page 14 page 15 page 16 page 17 chapter 1 quick. Diese informationen konnen sich ohne vorherige ankundigung andern. Building on the phenomenal success of the industrystandard agilent 34401a, these new meters offer improved accuracy, expanded measurement capability, dramatically improved measurement speed and throughput, and modern. Using labview driver for agilent 34401a ni community. The agilent 34410a and 34411a 61 2 digit dmms represent the latest generation of multimeters from agilent technologies.
It is always good to start with the getting started vi since it provides an example of how to use the 34401a subvis programmatically. The 34401a dmm will be discontinued december 1, 2016 and is replaced by nextgeneration 34461a truevolt series dmm. My problem is that the rate of data acquisition is very slow. Agilent technologies 34401a user manual pdf download. Programming and syntax guide for sidebyside scpi command comparison of the agilent u2741a 34405a, and 34410a34411a digital multimeters. Hello everyone, i am trying to connect my pc to a 34401a trhough spci commands rs232. Safety summary quick start tutorial connect the power cord. Use it on your benchtop the 34401a was designed with your bench needs in mind. Agilent 34401a multimeter uncompromising performance for benchtop and system testing product overview measure up to volts with 61 2 digits resolution 0. All of the 33220a product documenation is provided on the agilent 33220a product reference cd that comes with the product, and is also. Its combination of benchtop and system features ma.
If you have questions relating to the operation of the hp 34401a, call 18004524844 in the united states, or contact your nearest hewlettpackard sales office. Agilent 34401a connecting the 34401a to a pc using agilent. If you are considering replacing the 34401a in your test system, all you need to do is put the 34410a or 34411a in emulationmode using the system. The agilent 34401a are designed to safely withstand occasional transient overvoltages up to 2500 vpk. The agilent technologies 34401a multimeter gives you the performance you need for fast, accurate bench and system testing. Agilents powerful visa io library, drivers, and examples for the most popular programming development environments, so you are programming within minutes, not hours. The hp 34401a is capable of making highly accurate measurements. Agilent 531a2a 225 mhz universal counter programming guide manual part number 53190044 printed in malaysia. Octopart is the worlds source for 34401a availability, pricing. Voltages above 300 vac may be measured only in circuits that are isolated from mains.